CN

13823605006

How to manufacture a wafer film coating machine

How to Manufacture a Wafer Film Expansion Machine: Design Principles of the Wafer Film Expansion Machine: A wafer film expansion machine is a film expansion clamping device comprising an upper base, a lower base, an upper clamping plate and a lower clamping plate. Guide rods and drive rods are provided between the upper and lower bases; both ends of the guide rods are connected perpendicularly to the upper and lower bases respectively, the lower end of the drive rod is pivotally mounted within the lower base, whilst its upper end passes through the upper base and is rigidly connected to the output shaft of the drive motor via a coupling; the shaft of the drive rod is provided with a first lead screw section and a second lead screw section, each with opposite threads,

US-based EIT UV POWER PUCK II four-channel and single-channel UVI CURE PLUS II energy meter calibration and repair service company

EIT UV POWER PUCK II (four-channel and single-channel) and UVI CURE PLUS II energy meters: calibration and repair services. Where can I have my UV energy meter calibrated? Where can I have my UV energy meter repaired? Which company can calibrate the US EIT UV POWER PUCK II four-channel and single-channel UVI CURE PLUS II energy meters? Which company can repair US EIT energy meters? Where can the US EIT UV POWER PUCK II four-channel and single-channel UVI CURE PLUS II be calibrated and repaired?

EIT UV Energy Meter Calibration Organisation, USA

Where can the US EIT UV power meters – the US EIT UV POWER PUCK II (four-channel) and the single-channel UVI CURE PLUS II – be calibrated? 1. The organisation responsible for the calibration and commissioning of the US EIT UV POWER PUCK II (four-channel) and the single-channel UVI CURE PLUS II power meters is Shenzhen Deshengxing Electronics Co., Ltd. Please note the fault details on the repair form. The return address for repairs and calibration is: 3rd Floor, Building 5, No. 1 Fuda Road, Zhangmutou Town, Dongguan City. Attn: Jianni, 15989

What are the points to bear in mind when using LEDs?

What precautions should be taken when using LEDs? Precautions during use: When using this product, do not touch it directly with your hands, as this may contaminate the surface of the LED and adversely affect its optical properties. Furthermore, this may cause the product to become misshapen or the wires to break, resulting in the LED failing to light up. When using tweezers, take care not to apply excessive force to the LED, as this may result in damage, chipping or flaking of the glass component, product deformation or broken wires, causing the LED to fail to illuminate. Dropping the product may result in

Faults and Repairs for the US EIT Energy Meter (Complete Guide)

Repair and fault diagnosis for US EIT energy meters (comprehensive guide): Where can the US EIT UV POWER PUCK II (four-channel) and single-channel UVI CURE PLUS II be calibrated and repaired? For the above enquiries, please contact us directly for a professional response. Shenzhen Deshengxing Electronics Co., Ltd. specialises in the repair and calibration of US EIT 1, US EIT UV POWER PUCK II (4-channel and single-channel) and UVI CURE PLUS II energy meters. Calibration and commissioning services are provided by: Shenzhen Deshengxing Electronics Co., Ltd. Meters awaiting repair

Points to Note in UV LED Design

Points to Note in UV LED Design Although Nichia recommends the use of copper circuit boards for mounting this product, copper circuit boards may cause the glass lens to crack or lead to solder cracking due to the heat generated during reflow soldering; therefore, it should be verified in advance that the reflow soldering process will not adversely affect this product. During processes such as PCB cutting after installation, bending of the PCB may cause the outer packaging to crack; therefore, when determining the LED configuration, care should be taken to

UV energy meter calibration, data debugging and repairs

UV energy meter calibration, data adjustment and repair: If your UV energy meter is displaying inaccurate data, significant deviations or results that do not match existing standards, do not panic – simply send it to us for adjustment. Shenzhen Deshengxing Electronics Co., Ltd. can calibrate UV energy meters. Regarding UV energy meter calibration, please note the following: 1. Existing reference meter: this refers to the meter you have been using for testing. Customers requiring their UV energy meter to be calibrated against the original reference must provide the original

Precautions against static electricity should be taken when using UV LEDs

Precautions for Anti-Static Measures When Using UV LEDs: This product is sensitive to static electricity and surge voltages; exposure to such conditions may damage the chips, thereby compromising the product’s reliability. Therefore, the following anti-static measures should be implemented during operation. Use anti-static wrist straps, conductive clothing, conductive footwear and conductive flooring to dissipate static charge; ensure that equipment and tools within the work area are earthed to dissipate static charge; and utilise workbenches and storage areas constructed from conductive materials.

Differences in the DISCO TAIKO Manufacturing Process

DISCO TAIKO Process: Distinct from the TAIKO Process. The TAIKO Process is a new technology for wafer back-grinding developed by DISCO. Unlike conventional back-grinding techniques, this technology preserves the outer edge of the wafer (approximately 3 mm) whilst grinding only the inner circular area to achieve thinning. The introduction of this technology helps to reduce the risk of damage during the handling of thin wafers and minimises warping. Advantages of the “TAIKO process”: By leaving a rim around the periphery of the wafer, the wafer

How do UV LEDs dissipate heat?

How to dissipate heat from UV LEDs and how to manage heat dissipation in UV LED luminaires: Heat generation must be controlled during the use of this product. The temperature of the chips in the driver is affected by the thermal resistance of the circuit board and the LED packing density; therefore, care must be taken during circuit board design to dissipate heat effectively and ensure that the LED junction temperature (TJ) does not exceed the absolute maximum rating. The drive current for this product should be determined based on the ambient temperature (TA), and the heat generated must be dissipated. The junction temperature (TJ) can be calculated using the following two methods:

How is the illuminance of a Nichia lamp calculated?

How is the illuminance value of Nichia lamps calculated? Many major UV LED manufacturers provide a professional specification sheet for each model of UV LED chip. One item listed on the specification sheet is ‘Radiant Flux’, measured in (mW). This value is what we refer to as illuminance or luminous power density; it does not refer to electrical power, but rather to the portion of light power that is UV after photoconversion. In other words, it is UV intensity. Now, let us look at the specifications provided by the original manufacturer, NICHIA of Japan, in their technical data sheets:

How do you clean a UV LED?

How should UV LEDs be cleaned? It is best not to clean this product. If cleaning is unavoidable, you must first ensure that the cleaning agent will not adversely affect the outer casing or the glass lens. Furthermore, CFC solvents are banned worldwide. Ultrasonic cleaning should ideally not be used on this product, as the output power of the ultrasonic cleaner and the method of circuit board mounting may adversely affect the LEDs. If ultrasonic cleaning cannot be avoided, it must be confirmed in advance that it will not