CN

13823605006

Product Centre

UV Energy Meter Repair and Calibration Services

Product Overview

Regarding calibration: For customers requiring calibration, our company submits the instruments to the relevant national authority, and a certificate is issued by the National Institute of Metrology. CNAS-accredited, SMQ-certified.

Product Specifications

For customers requiring calibration, our company submits the instruments to the relevant national authority, and a certificate is issued by the National Institute of Metrology. CNAS-accredited, SMQ-certified

 

Shenzhen Deshengxing Technology Co., Ltd. has long been providing UV energy meter certification services to a wide range of clients, issuing calibration reports from the National Institute of Metrology, an authoritative third-party body.

Customer Information on UV Energy Meter Calibration

Customers requiring calibration of their UV energy meters should note the following:

1. Customers who require their UV energy meters to be calibrated to the original standards must provide at least five sets of data from tests carried out on the original UV energy meter under specified conditions. These five sets of data must be the results of individual measurements; they must not be cumulative.

Please also provide no fewer than five sets of data measured using the new standard UV energy meter under the same, unchanged conditions; these figures must not be aggregated either. Simply provide these two sets of data, clearly labelled, and return the UV energy meter requiring calibration to our company together with the test data.

2. Customers who do not have a reference standard of their own may use their newly purchased UV energy meter as a reference; there is no need to return it for calibration for a certain period of time.

3. Customers who have recently purchased a UV energy meter and have already submitted the product for testing to the National Institute of Metrology, but who require our company to carry out a functional calibration again, must provide a copy of the metrological report issued by the National Institute of Metrology or the correction factors,

If standard reference values under equivalent conditions cannot be provided, we will be unable to carry out the calibration as we have no basis for comparison.

4. Many customers send their UV energy meters to the National Institute of Metrology for testing; however, if there is a fault with the product itself, the Institute will not issue any written report.

If the Metrology Institute has issued the relevant metrology certificate, this indicates that the product itself has no quality issues. The certificate will also specify three sets of data: the standard value, the displayed value and the correction factor.

Many customers are easily confused by this point; they assume that if the displayed value deviates from the standard value, the UV energy meter is substandard. However, this is not the correct interpretation. This is because the standards for UV energy meters vary from country to country, and national standards are not harmonised,

This phenomenon is therefore perfectly normal. If, under standardised conditions, the readings from a UV energy meter show significant discrepancies—for example, if three measurements yield readings of 500, 210 and 400 respectively—this indicates that the UV energy meter has a quality issue. In such circumstances, the Metrology Institute will not issue any written report.

5. Fees

Functional Calibration: If a UV energy meter purchased from our company requires calibration, this service is provided free of charge for the first two years. After two years, a charge based on market rates will apply. For other customers, a fee of 200 yuan per calibration applies.

Metrological calibration: If the equipment needs to be sent to a metrology institute for calibration and the issuance of a calibration certificate, Deshengxing customers will be charged in accordance with the metrology institute’s standard rates. Other customers will be charged an additional service fee of 100 yuan.

All shipping costs for returns are to be borne by the customer.

Metrology Institute Calibration Report (Fig.)

Regarding repairs:

UV dosimeter repairs, EIT dosimeter repair manufacturers, EIT dosimeter repair prices.

Shenzhen Deshengxing Technology specialises in the repair of all types of UV energy meters, offering competitive repair rates. All imported spare parts required for imported UV energy meters are clearly priced, and we charge very reasonable repair fees.

We specialise in the repair of UV energy meters from various brands, including the American EIT, the German UV-int150 and the Japanese ORC. We also undertake repair services such as battery replacement, display replacement and sensor replacement for all types of UV energy meters,

We can also arrange for samples to be sent on behalf of clients to the National Institute of Metrology for testing by accredited bodies, and issue metrological reports.

Repair Case Study 1 [Screen Replacement]

EIT (USA) single-channel UV energy meter, UVICURE PLUS II, serial number: S/N 17573

Fault diagnosis: The item was left in the UV curing unit and not removed in time, resulting in human error that caused the display screen to be damaged by high temperatures.

Photos taken before the repair:

Photos after repair:

The repair was successful, and the display is now working properly:

As the camera angles differed before and after the repair, there is some glare; readers may wish to compare the three photos above carefully—they show the same instrument, and the serial number has remained unchanged throughout.

 

Repair Case Study 2 [Battery Replacement]

Repair Case Study 3 [Sensor Repair]

Procedure for reporting faults with UV energy meters:

Customers requiring repairs should send their damaged equipment to our company by courier. Our staff will sign for the delivery, diagnose the fault and then provide the customer with a quotation. Repairs will be carried out with the customer’s consent. The equipment will be returned once payment has been received.

The warranty period for repairs varies depending on the specific repair work, ranging from six months to one year. Repair costs are collected via courier on delivery within Guangdong Province; for orders outside the province, goods will be dispatched only upon receipt of payment.