[Produced by Jinjian] How should the sterilisation effectiveness of UV LEDs be assessed?
According to the ‘Diagnosis and Treatment Protocol for Pneumonia Caused by Novel Coronavirus Infection (Trial Version 4)’, published on 28 January 2020 by the National Health Commission and the State Administration of Traditional Chinese Medicine, it states:The virus is sensitive to ultraviolet light and heat. In other words, ultraviolet light can kill the novel coronavirus (2019-nCoV).
As ultraviolet raysThanks to increases in LED power output and technological advances, LEDs have gradually replaced lower-power mercury-based UV lamps on the market, owing to their safety, environmental friendliness, compact size and the absence of chemical residues.Based on a review of previous UV-LED disinfection and sterilisation test cases, Jinjian Laboratories has concluded that factors such as brand, LED chip and luminaire type, wavelength, luminous efficacy, irradiation distance, irradiation time, irradiance, penetration rate and field of application influence the results of disinfection and sterilisation validation tests for UV-LEDs as compared to mercury-vapour lamps.
In this article,We have outlined three experiments to illustrate the importance of several factors, and recommend that customers scientifically design their experimental conditions and carry out evaluations based on the specific product performance and application area.The germicidal efficacy of UV-LED lamps.
I. Comparison of the bactericidal efficacy of the same product against different bacterial strains
A client commissioned Jinjian Laboratories to carry out germicidal testing on UV LED luminaires. Jinjian’s engineers found that the central wavelength of this luminaire was275 nm, at a distance of 1 m, the radiation intensity is 98 μW/cm 2, the bactericidal effects on Candida albicans, Staphylococcus aureus and Escherichia coli were evaluated after 15 minutes of vertical irradiation, in comparison with the control group. The results of this experiment showed that, although UV LEDs of the same type had the same radiation intensity, their bactericidal effects varied across different bacterial species.
II. Comparison of the effects of different exposure times for the same product
A client commissioned Jinjian Laboratory to conduct comparative sterilisation tests on UV LED chips under different conditions. Jinjian engineers tested the supplied UV LED chips, which had a central wavelength of 280 nm, and evaluated their sterilising effect on E. coli after vertical irradiation from above the culture medium for 30 seconds, 40 seconds and 50 seconds. The results of this trial demonstrated that, at the same irradiation distance, the bactericidal efficacy of the UV LED increased significantly as the irradiation time increased; this particular UV LED lamp exhibited good bactericidal efficacy against E. coli after 50 seconds of irradiation. The test results are shown below:
III. Comparison of effects at different irradiation distances for the same product
A client commissioned Jinjian Laboratory to conduct bactericidal testing on UV LED chips. Jinjian engineers determined that the central wavelength of this UV LED chip was 275 nm. The bactericidal efficacy against Staphylococcus aureus was evaluated after irradiation for 60 seconds at vertical distances of 5 cm, 7 cm and 10 cm above the culture medium. In this trial, the bactericidal efficacy of the UV LED lamp decreased significantly as the distance increased, whilst the irradiation time remained constant; at a distance of 5 cm, it demonstrated good bactericidal efficacy against Staphylococcus aureus. The test results are shown below:
Compared with traditional UV lamps, Jinjian Laboratories believes that the following differences should be taken into account when designing UV-LED disinfection experiments:
1. Band:Ultraviolet light in different wavelength bands has varying levels of effectiveness in killing bacteria and viruses.Traditional UV mercury lamps generate ultraviolet radiation, predominantly at a wavelength of 253.7 nm, through electrical discharge; however, according to the latest research findings, the germicidal efficacy of ultraviolet light may be higher at around 264 nanometres. Standardisation in the field of deep-ultraviolet (UVC) LED disinfection faces a series of challenges. For instance, whilst mercury vapour lamps primarily emit germicidal radiation at 253.7 nm, UVC LEDs have wavelengths mainly distributed between 200 and 280 nm, which introduces a number of differences for subsequent application solutions.
2. Ultraviolet dose:Sterilisation requires sufficient irradiation intensity, sufficient duration and the appropriate wavelength range.The intensity of ultraviolet radiation depends on factors such as the luminous intensity of the effective spectrum of the ultraviolet light source, the light output angle of the lamp (beam concentration) and the distance between the lamp and the object being irradiated. Generally speaking, the higher the radiation intensity, the better the effect; the more concentrated the beam is on the surface of the object being irradiated, the better the sterilisation effect; the closer the distance to the object being irradiated, the better the effect; and the longer the cumulative irradiation time—that is, the total time the object spends under the UV lamp—the better the effect.
3. Luminous efficiency:At present, UV LEDs are not yet able to fully replace mercury lamps in terms of luminous efficiency and other factors.UVA LED technology is now relatively mature, with EQE reaching 50–60%; future work on UVA products will focus more on development at the application system level. The external quantum efficiency (EQE) of deep-ultraviolet LEDs in the UVB and UVC bands remains relatively low, generally below 10%, with commercial products typically ranging from 1% to 3%.
4. Areas of application:Ultraviolet LEDs also offer advantages such as compactness, portability, environmental friendliness, safety and ease of design, which may give rise to application requirements that differ from those of traditional mercury lamps.. For example, the portable electronic disinfection devices, lift handrail sanitisers and robotic vacuum cleaners that are already available. These are areas where traditional UV light sources are difficult to apply.
5. Ultraviolet transmittance:UV LEDs are highly effective at inactivating the surfaces of objects when shone directly upon them, but they do not penetrate deeply,There is no noticeable effect on the interior of objects that do not allow light to pass through, or on covered areas; however, traditional UV lamps can utilise the diffusive nature of the ozone they generate to compensate for the shortcoming that UV light travels only in straight lines, thereby creating blind spots in disinfection.
6. Differences in sterilisation:There are significant differences in the sterilising effectiveness of UV lamps of different brands and specifications,When selecting lighting, ensure you check the light source’s radiation wavelength, radiation intensity, protective design and operational requirements, and choose the appropriate luminaire.
Jinjian LaboratoryAs a third-party laboratory specialising in LED quality management, having obtained certification including the Qualification Accreditation for Inspection and Testing Bodies (CMA), laboratory accreditation from the China National Accreditation Service for Conformity Assessment (CNAS) and the ISO 9001 Quality Management System, we are pleased to launch “UV LED Sterilisation Experiment” service offering.Taking into account factors that influence the results of disinfection and sterilisation testing—such as brand, LED chip and luminaire type, wavelength, luminous efficacy, irradiation distance, irradiation duration, radiation intensity, penetration rate and field of application—we collaborate with clients to design experimental protocols and scientifically evaluate the germicidal efficacy of UV-LED lamps.
These include optimised test plans:
1. Comparative testing of different bacterial strains
2. Comparative testing of sterilisation efficacy at different irradiation distances
3. Comparative testing of the bactericidal efficacy at different exposure times
4. Comparative testing of sterilisation efficacy at different radiation intensities
5. Comparative testing of different products under the same test conditions
Staphylococcus aureus, Escherichia coli, Pseudomonas aeruginosa, Staphylococcus albus, Mycobacterium chelonae subsp. abscessus, spores of Bacillus subtilis var. niger, Candida albicans, etc.
Note:Staphylococcus aureus ATCC 6538 serves as a representative of pyogenic cocci amongst bacterial vegetative cells;
Escherichia coli 8099 serves as a representative of intestinal bacteria in bacterial propagules;
Pseudomonas aeruginosa ATCC 15442 serves as a representative of the bacterial strains most frequently isolated in hospital-acquired infections;
Staphylococcus albus 8032 as a representative of airborne bacteria;
Mycobacterium tortis subsp. abscessus ATCC 93326 as a representative of Mycobacterium tuberculosis;
Bacillus subtilis var. niger spores, ATCC 9372, as a representative example of bacterial spores;
Candida albicans ATCC 10231 serves as a representative of pathogenic fungi.
‘Technical Specifications for Disinfection’, ‘GB 28235-2011 Safety and Hygiene Standards for Ultraviolet Air Disinfectors’, ‘HJ 2522-2012 Technical Requirements for Environmental Protection Products – Ultraviolet Disinfection Devices’ , ‘WST 367-2012 Technical Specifications for Disinfection in Medical Institutions’ and the Jinjian Laboratory corporate standards.
I. Advantages of deep-ultraviolet (UV) LED sterilisation and disinfection:
1. Highly effective sterilisation: The killing or inactivation of bacteria and pathogens generally takes place within a few seconds; it is virtually instantaneous.
2. Broad-spectrum antimicrobial activity: It is highly effective at killing almost all bacteria and viruses.
3. No secondary pollution: No other chemical pollutants are produced.
II. Classification by Ultraviolet Wavelength Band
Classification of the ultraviolet spectrum by wavelength:
UVA:315–400 nm (near-ultraviolet, NUV 365–400 nm), with applications including curing, photocatalytic purification and anti-counterfeiting.
UVB:280–315 nm,Applications include eye health/medical care and the regulation of plant growth through lighting, amongst others.
UVC:200–280 nm (solar blind – “sun-blind” ultraviolet radiation),Used for sterilisation and disinfection of substances such as water and air.
III.The Principle of Ultraviolet Disinfection
Ultraviolet disinfection technology is based on research in modern epidemiology, medicine and photodynamics, and is achieved using specially designed, high-efficiency, high-intensity and long-life UVC-band ultraviolet lamps.Ultraviolet radiation kills microorganisms (such as bacteria, viruses and spores) by causing radiation damage and disrupting the function of their nucleic acids, thereby achieving the purpose of disinfection and sterilisation; the inactivation effect depends on the dose of ultraviolet radiation.
Microbial Structure and the Mechanism of UV Inactivation:
IV. Class I and Class II Disinfection Products
The National Health and Family Planning Commission (NHFPC) has introduced relevant policies requiring that Class I and Class II disinfection products undergo a health and safety assessment—either independently or through a third party—prior to their initial market launch; only those products that pass this assessment may be placed on the market. In other words, prior to market launch, a third-party testing and assessment body must be commissioned to carry out a health and safety assessment and issue a professional test report, which must then be filed with the government before the product may be placed on the market.
Class I disinfection productsThis refers to disinfection products that carry a higher level of risk and require strict management to ensure their safety and efficacy. These include high-level disinfectants and disinfection devices for medical devices, germicides and germicidal devices, skin and mucous membrane disinfectants, biological indicators and chemical indicators of disinfection efficacy.
Class II disinfection productsThis refers to disinfection products classified as posing a moderate risk, which require enhanced management to ensure their safety and efficacy. These include disinfectants, disinfection devices and chemical indicators (excluding Class I products), as well as packaging for sterilised items bearing a sterilisation label and antibacterial (or bacteriostatic) preparations.