The lethal dose of ultraviolet radiation for the 2019-nCoV novel coronavirus is 1085 mJ/cm².

The lethal dose of ultraviolet radiation for the 2019-nCoV novel coronavirus is 1085 mJ/cm².

UVC-LEDDeep Ultraviolet Disinfection2019-nCoVA Brief Summary of the Investigation Report on the Dosage of the Novel Coronavirus Vaccine

Abstract:According to the literature,BetacoronavirusThe virus belongs to the coronavirus genus, such asSARS、MERSThe UV inactivation dose is given asTCID50The initial concentration is approximately105.8 /mL的2019-nCoVNovel coronavirusNCP的99.99%The lethal dose of ultraviolet radiation is1085 mJ/cm2, provides reference values for deep ultraviolet light in surface disinfection and air purificationLEDBase models are used in the development of various types of applications.

 

1, Background Information

It has now been more than two months since the outbreak of the novel coronavirus in Wuhan, and substantial medical resources have been channelled into patient admission, the development of treatment methods, the screening of effective drugs, and the prevention and control of the spread of the outbreak. The ‘Treatment Protocol for Pneumonia Caused by Novel Coronavirus Infection (Trial Version 4)’, issued by the National Health Commission,[1]as mentioned in“Our understanding of the physicochemical properties of coronaviruses derives largely fromSARS-CoV和MERS-CoVResearch. The virus is sensitive to ultraviolet light and heat,56℃30minutes, diethyl ether……Effectively inactivates viruses……”. These physicochemical properties of coronaviruses make it feasible to use ultraviolet (UV) disinfection technology to inactivate coronaviruses on various surfaces, in the air and in water; as a result, a large number of UV devices have been deployed in environments with high viral concentrations, such as hospitals.[2, 3]. UltravioletLEDIndustry news reports also mention that a research team led by Dong Xiaoping, an expert at the National Institute for Viral Disease Control and Prevention under the Chinese Centre for Disease Control and Prevention, has discovered that when the intensity exceeds90 μW/cm²的UVCExposing the coronavirus to radiation,30It can be killed in just a few minutesSARSVirus[4]. So far, no more quantitative data on the novel coronavirus has been seenNCP 2019-nCovstatements or experimental data regarding the lethal dose of ultraviolet radiation. However, in the practical application of ultraviolet technology, the operating environment, target inactivation rate, and ultraviolet intensity and dose are technical parameters that must be taken into account. A lack of quantitative experimental data will render ultraviolet lamps or ultravioletLEDIts application remains at a qualitative or empirical level.

Of course, given the limited experimental resources available, the actual conduct of research into the novel coronavirusNCP 2019-nCoVThere are significant difficulties in conducting studies on the UV inactivation dose and kinetics. Therefore, inSARSDuring the outbreak, with regard to murine hepatitis coronavirus (Mouse Hepatitis Virus,MHV) has contributed to the discovery and identification ofSARSIt provides an excellent scientific basis for understanding its physical and chemical properties. It is understood that[5], Coronaviruses comprise four genera, namelyAlphacoronavirus,Betacoronavirus,DeltacoronavirusandGammacoronavirus. Highly pathogenic coronavirusesSARS-CoV和MERS-CoV, as well as model viruses used in research into the molecular virology of coronavirusesMHVall fall underBetacoronavirus. The genome of this virus consists of a single-stranded positive-sense strandRNA, approximately30,0000A nucleic acid, belonging to the largest genomeRNAOne of the viruses.MHV、SARS-CoV、MERS-CoV及NCP 2019-nCoVThey exhibit a high degree of homology and structural similarity; consequently, their resistance to ultraviolet radiation is similar and serves as a point of reference for one another.

Based on the above facts, this paper reviews the literature on various coronaviruses, such asSARS-CoV、MHV-Cov, research data on UV inactivation, showing the time required to inactivate viruses on surfaces and in the airUVCA summary of UV dose levels and influencing factors is provided to serve as guidanceUVC-LEDProduct development. The specific virus culture and experimental procedures are not the focus of this paper; please refer to the references, as they will not be elaborated upon here. Furthermore, bearing in mind that in the year the references were published, deep ultravioletUVC-LEDAs it is not yet a widely adopted technology, the light sources used are all ultraviolet mercury lamps; this does not mean, however, that they are suitable for deep ultravioletUVC-LEDThe design proposal is of no practical use. Furthermore,275 nmDeep ultravioletLED和254 nm The disinfection efficiency of UV lamps is the same; here, the disinfection data for these lamps can also be compared to that of deep UV.LED。

 

2, the UV dose required to inactivate coronaviruses on surfaces

US Food and Drug Administration Centre for Bioevaluation and ResearchTaylorTeam2004年[6]和2006年[7]Research has shown that at the characteristic wavelength254 nm, radiation intensity4016 μW/cm²When irradiated by a deep-ultraviolet light source,TCID50The initial concentration is approximately105.8/mL的SARS-CoVVirus samples are in1 minThe latter part was wiped out, in6 minsNumber of survivors~10 per millilitre, eradication rate99.99%That is all;10 mins后≤1.0 TCID50 (log10) /ml, the eradication rate can be considered to be>99.9999%. The table also shows the eradication rateLOGThe value is positively correlated with the cumulative radiation dose (in this case, the duration of exposure), and atLOGless than4There is a linear relationship in the anterior region. So, in105.8 /mLAt viral concentrations,99.99%The UV dose required to achieve a kill rate of1445 mJ/cm2. Based on the elimination rate just mentionedLOGIt is not difficult to derive the rule that there is a linear relationship between the value and the dose,99.9%The dose required to achieve a kill rate of722 mJ/cm2. AndUVAAlthough it is possible to utilise photocatalysis to generate reactive oxygen species and thereby destroy viruses,RNAchain, butUVAUltraviolet (365 nm,2133 μW/cm²) toSARS-CoVIt has no virucidal effect against coronaviruses.

Dong Xiaoping’s team[8]于2003Annual reporting intensity>90 μW/cm²的UVCExposing the coronavirus to radiation,60It can be killed in just a few minutesSARSVirus (note that the original text reads60 minsrather than as stated in previous news reports30 mins), converted cumulative dose324 mJ/cm2, lower thanTaylorThe team’s1445 mJ/cm2, possibly due to differences in experimental conditions or the origin of the viral samples, and as the data from Dong Xiaoping’s team do not provide specific detailsLOGvalue, so it exists5Difference in effectiveness (as reflected in the kill rate)LOGThe value is merely0.5). From the perspective of performance redundancy, it is recommended that application manufacturers, when designing their solutions, adhere to99.99%Eradication rate in relation to requirements1085 mJ/cm2Dosage.

Following the spread of the epidemic earlier this month, we determined an initial concentration of approximately, based on the lethal dose of the novel coronavirus as reported in several literature reviews from both China and abroad,105.8/mLThe novel coronavirus,99.99%The predicted UV lethal dose corresponding to the kill rate is1445 mJ/cm². This dose is inaccurate and needs to be corrected. It is a dose calculated by multiplying the optical power density by time. This line of reasoning overlooks one detail, namely that thisSARSThe test scenario is a height of1 cman aqueous solution, using the surface of the4016μW/cmIt is inaccurate to calculate the irradiation dose for the entire solution based on the intensity at a height of ². Irradiation intensity is inversely proportional to the square of the distance. Consequently, the irradiation intensity at the bottom of the solution differs from that at the top. When calculating the cumulative dose, a linear average should be taken.LEDThe light is emitted from a small area, approximating a point source, and the distribution across the illuminated surface is uneven; taking into account1 cmAs the fluctuations within this range are minor and have little impact, we can approximate the average here. Furthermore, aqueous solutions with regard toUVCabsorption; previous studies have mentioned that pure water has an effect on275 nmAbsorption is relatively low, and the density of the virus particles is limited; therefore, water absorption need not be taken into account here. Following integration over the entire depth, the lethal dose of the novel coronavirus is hereby formally revised to1085 mJ/cm2, for the information of our colleagues in the industry.

The following were used in the eradication experiments:SARS-CoVThe virus is dispersed in a phosphate solution, which is analogous to its presence on surfaces and in water. Of course, it has been demonstrated that coronaviruses in tissue fluids, such as blood, cannot be directly inactivated by ultraviolet radiation.[7]。

It is worth noting that gamma rays, which damage both normal human cells and cancer cells (at doses as high as15,000 rad) With regard toSARSIt has virtually no virucidal effect.

 

3, the UV dose required to inactivate coronaviruses in the air

在50 × 260 × 455 mm(Gao×宽×(length), with a flow velocity of12.5 L/minIn the single-loop air duct, the concentration of aerosolised virus introduced was104~105 PFU/mL, humidity50%Rhthe air. Use36WUltraviolet mercury lamps (ozone-free) from the pipeline455 mmFor inward irradiation, adjust the intensity of the ultraviolet radiation immediately adjacent to the window to599 μW/cm², stable operation15 minsFollowing this, sampling was carried out at the single-circuit air outletMHVThe inactivation rate of the coronavirus compared with the control group was87.8%。Table 2The data also indicates that the inactivation rate of viral aerosols is higher in conditions of high humidity.

The above data provides empirical support for air disinfection scenarios and can be used to calculate, in broad terms, that in recirculation mode, to achieve2hours,30in the air within a cubic metre of spaceMHVCoronavirus inactivation rate87.8%, you need to use10 mW 275 nm UVC LEDLED chip320 pieces, which is far greater than the number of LED chips in a natural bacterial environment (according to theoretical calculations2–4 pcs[10](…which is related to the product’s composition). E. coli99.99%The surface kill dose is approximately13.2 mJ/cm2, in Section 2 of this paperSARSThe dose required for the virus is its110times, which is broadly consistent with the dose factor required for air purification. Therefore, in order to apply this in practical scenarios, it is necessary toUVC-LEDWorking hours have been changed to24 hoursKeep it switched on, like this30Equipment required for a space of one cubic metreUVC-LEDThe quantity is27 pieces… and already meets the cost requirements for commercial applications. It is reasonable to assume that this dose-response relationship may also apply to still and flowing water.

 

4, toNCP 2019-nCoVNovel coronavirusUVCThe significance of reference values for UV inactivation doses

Experimental data indicate that,SARS-CoV在56℃Heat treatment below20 minsThis can be achieved99.999%The above eradication rates, in65℃The time required can even be reduced to10minutes. Although there are reports thatNCP 2019-nCoV在56℃Heat treatment below30 minsCan be killed. However, there is no direct comparison between heat resistance and UV resistance, soSARScannot be scientifically derived from its physical and chemical propertiesNCP 2019-nCoVIts UV resistance should be regarded as a guide only. University of Iowa, USAKurt Bedell, BSThe distance is given1.22Rice, which also belongs toBetacoronavirusOf the genus Coronavirus8.9×105 pfu/mLConcentration ofMHV-A59和MERS-CoVThe time required to kill them is as follows:10 mins和5 mins, with a twofold difference in the lethal dose[11]. However, as mentioned earlier,2The difference between double the dose is reflected in the kill rate.LOGThe value is merely0.3, inLOGWhen the base figure is high, that is to say99.9%和99.95%The difference is negligible in production.

   

5, Conclusions

With the virus raging, deep ultraviolet…LEDIt is the duty of companies in the industry to go further in the development of effective solutions and the supply of core components. In the hope that this article will serve as a starting point for further discussion, we hope that the ideas outlined herein will1085 mJ/cm2 99.99%Bactericidal rate and lethal dose (virus)TCID50The initial concentration is approximately105.8 /mL) and the corresponding surface disinfection and air purification models support various types of deep ultravioletLEDProduct development. We look forward to joining forces with like-minded manufacturers to combat the COVID-19 pandemic.

Further information

6, References

[1] National Health Commission. Treatment Guidelines for Pneumonia Caused by Novel Coronavirus (Provisional, Fourth Edition)[Z].2020.

[2] LEDinside.Here are some key facts you should know about UV sterilisation and disinfection during the pandemic![EB/OL].https://www.ledinside.cn/news/20200204-46872.html.

[3] China.com News: Combating the Novel CoronavirusWhat lessons can we learn from the SARS outbreak?[EB/OL].https://news.china.com/socialgd/10000169/20200121/37728369_all.html#page_2.

[4] Darnell M E R, Subbarao K, Feinstone S M, et al. Inactivation of the coronavirus that causes severe acute respiratory syndrome, SARS-CoV[J]. Journal of Virological Methods, 2004, 121:85–91.

[5] Darnell M E, Taylor D R. Evaluation of inactivation methods for severe acute respiratory syndrome coronavirus in non-cellular blood products[J]. Transfusion, 2006, 46(10):1770–1777.

[6] Duan S M, Zhao X S, Wen R F, et al. Stability of the SARS coronavirus in human specimens and the environment, and its sensitivity to heating and UV irradiation[J]. Biomed Environ Sci, 2003, 16(3): 246–255.

[7] Walker C M, Ko G. Effect of Ultraviolet Germicidal Irradiation on Viral Aerosols[J]. Environment Science & Technology, 2007, 41(15).

[8] Kurt Bedell B, Buchaklian A H, Stanley Perlman M. Efficacy of an Automated Multiple Emitter Whole-Room Ultraviolet-C Disinfection System Against Coronaviruses MHV and MERS-CoV[J]. Infection Control & Hospital Epidemiology, 2016, 37(5):598–599.

[9]References from DUVTEK    Edited by: Shenzhen Deshengxing Electronics Co., Ltd.www.uvstry.cn

How do you measure the UV index and UV intensity? The obvious choice is, of course,EIT Power Puck II (USA)