Main Components of a Plasma Cleaner

Main Components of a Plasma Cleaner

With the continuous development of our times and the constant advancement of science and technology, the production and research tools and equipment we use today are becoming increasingly sophisticated. This has significantly improved our productivity and helped us to make greater social discoveries and innovations. However, due to the cleanliness requirements in many industries and fields of research, traditional cleaning equipment is no longer able to meet these demands, whilst advancedPlasma cleanerIt has become the product of choice for customers, and its effective cleaning performance and thorough cleanliness have consistently received high praise. Well then,Plasma cleanerWhat is its main structure?

Plasma cleanerIt consists mainly of three parts:

1. Control unit. The currentPlasma cleanerIt primarily features four control units: automatic control, semi-automatic control, PC control and LCD touchscreen control. The control units mainly consist of a power supply, a control system, control buttons and an operating display.

2. Vacuum chamber. The vacuum chamber is the space used for cleaning objects; it primarily comprises the chamber itself and the stainless steel vacuum chamber. As vacuum sterilisation, antibacterial treatment and plasma cleaning are carried out inside, there are certain requirements regarding the chamber’s pressure resistance; it is therefore necessary to use a chamber constructed from higher-quality materials.

3. Vacuum pump. Plasma cleanerThe main power source is the vacuum pump, whose primary function is to evacuate the air from the vacuum chamber to create a vacuum environment, after which plasma cleaning can take place. Vacuum pumps are mainly classified into dry pumps and oil-sealed pumps. Dry pumps are primarily powered by electricity, whilst oil-sealed pumps are powered by petrol or diesel.

Plasma cleanerTips for use:

1. When performing a vacuum operation, please ensure that the three-way valve is set to the ‘closed’ position—i.e. with the arrow pointing downwards—then switch on the power supply and start the vacuum pump. Check whether the vacuum pump is rotating clockwise or anti-clockwise; if it is rotating clockwise, this is normal. Once the test is complete, switch off the power supply again.

2. Before starting the vacuum pump, please ensure thatPlasma cleanerConnect to the vacuum pump. Allow the vacuum pump to run for five minutes. At this stage, the plasma cleaner is switched off. After five minutes, a glow will appear inside the plasma chamber.

3. When evacuating the system, open the three-way valve to connect it to the ambient air in the room, then open the needle valve slightly to allow air to enter gradually.Plasma cleanerinside the chamber to create a plasma, then switch on the power supply via the control panel at the front.

4. When performing plasma treatment, the sample should be treated for the specified duration. Once the treatment is complete, switch off the RF power and finally shut down the plasma cleaner.